Skip to content
+49 (0)2631 913-0|info@raab-gruppe.de
  • Raab-Academy
  • Career
  • Encyclopedia
  • FAQ
  • Sitemap
  • German
Raab-Gruppe Logo Raab-Gruppe Logo Raab-Gruppe Logo
  • Home
  • Brands
    • Raab
      • Raab Academy
      • Raab-Center
      • Planning software
    • Kutzner + Weber
      • Services
        • Sound measurement
        • Funding programms
    • NET
      • Services
      • Industry solutions
        • Bakery industry
        • Commerce and industry
  • Products
    • Raab
      • Alloy surcharge
      • Air-Stream
      • DW
      • DW-Alkon
      • EW
      • EW-Alkon
      • EW-Flex
      • Synthetic gas flue systems
      • LB LAS-FB
      • LB shaft L90
      • LB Universal
      • Super-Flex
      • Accessories for chimney cowl
      • Wall duct
    • Kutzner+Weber
      • Flue gas damper
      • Particle separator
      • Chimney fan
      • Silencer
      • Draught regulator
      • Accessories
    • NET
      • General description heat exchanger
      • Thermojekt® G and GB
      • Thermojekt® R and RB
      • Thermojekt® SK
      • Control engineering
      • Accessories for NET heat exchanger
  • Downloads
    • Raab
      • Approval & Planning
      • Assembly instructions
      • Brochures & Price Lists
      • Datanorm article data
      • Order forms
      • Product brochures
    • Kutzner+Weber
      • Assembly instructions
      • Brochures
      • Certificates
      • Datanorm article data
      • Pricelists
    • NET
  • References
  • News & Events
    • News
    • Events
    • Web-Seminare
  • About us
    • Company
      • History
      • Chronicle
    • Quality management
      • Certification
      • Disposal
    • Career
  • Contact
    • Distribution partners

Special silencers

  1. You are here:
  2. Home
  3. Portfolio
  4. Special silencers
Special silencersHeartbit2023-08-08T14:49:14+02:00
  • Description

  • Application area

  • Benefits

  • Type series

  • Downloads

  • FAQ

  • Description

The passive special silencers

When it gets really tight.
Due to the sometimes very small space conditions in boiler rooms, silencer solutions with standard products are not always possible. Here, specially designed silencers are used, which, for example, have to be designed at certain angles or have their connections at a specified position.

The Kutzner + Weber production is well prepared for these market requirements and has already realised many a “creative” silencer solution.

The concentric flue gas silencers

Supply air and flue gas all in one.
These silencers have been specially developed for installation in concentric flue gas systems with a nominal width of 80/125 mm. The construction of the actual muffling compound corresponds to that of the passive silencers of the AGM model series. They are double-walled so that the combustion air can be drawn in through the annular gap and are designed for condensing boiler systems, among others. They have a condensate drain as standard.

Range of use:

  • For nominal width 80/125 mm
  • Concentric design
  • Suitable for LAS operation

The reactive resonators

A special solution needs little space.
Reactive resonators can be used to reduce individual, protruding level peaks. These resonators are flanged to the side either on a T-piece or on a passive silencer.

The reactive resonators are designed without fibre material and are therefore wear-free, maintenance-free and robust.

Benefits:

  • For reducing level peaks up to 10 dB
  • For low frequencies up to max. 400 Hz
  • Extremely small space requirement

The passive silencers for large systems

Large nominal widths also possible.
The silencers of the ARE model series are designed for large systems and are available from a nominal diameter of 400 mm.

Structure
The damping material consists of mineral fibre. This mineral fibre is protected from abrasion by a stainless steel fleece. Perforated sheeting is used for shaping and stability. The bases of the silencers are welded to the shell. This means that these silencers can be used for larger overpressures. A condensate drain is included as standard.

Mode of operation
The mineral fibre used by Kutzner + Weber has a very fine and open-pored structure. The noise reduction in the passive silencers is achieved by the fact that the sound releases its energy through friction on its way through these fibres. In order to find the optimal mineral fibre, various types were acoustically tested according to DIN EN 29053-B at the Fraunhofer Institute for Building Physics, whereby the flow resistance was determined.

Silencing properties
The passive silencers are particularly suitable for reducing the sound level of medium and high frequencies. Their optimum damping power is available between 1000 and 2000 Hz.

Range of use
The silencers of the ARE model series are suitable for use with all standard furnaces and can be used without restriction with condensing boiler systems.

  • Application area

  • Overpressure tight up to 5000 Pa
  • Flue gas temperature up to 400 °C
  • Nominal widths 400 to 800 mm
  • Outlet silencer with adapted mounting possible
  • Benefits

  • Long service life due to high-quality stainless steel 1.4571/1.4404
  • Hydrophobic, condensate-repellent mineral fibre
  • Mineral fibre protected by perforated sheet
  • Acoustically tested mineral fibre according to DIN EN 29053-B (flow resistance)
  • Type series

  • Downloads

Here you have the possibility to download the brochures you are interested in as PDF files.

All brochures

Product sheet Silencer (PDF)

  • FAQ

Frequently asked questions and answers about silencers

FAQ

Products

  • Raab
    • Air-Stream
    • DW
    • DW-Alkon
    • EW
    • EW-Alkon
    • EW-Flex
    • Synthetic gas flue systems
    • LB shaft L90
    • LB Universal
    • LB LAS-FB
    • Super-Flex
    • Accessories for chimney cowl
    • Wall duct
  • Kutzner+Weber
    • Flue gas damper
      • IK 250
      • Motor-driven flue gas dampers
      • Thermally controlled flue gas dampers
    • Particle separator
    • Chimney fan
    • Silencer
    • Draught regulator
    • Accessories
  • NET
    • Thermojekt® G and GB
    • Thermojekt® R and RB
    • Thermojekt® SK
    • Accessories for NET heat exchanger

Informations

  • Raab Academy
  • Career
  • Downloads
  • Internal Downloads Login
  • Encyclopedia
  • FAQ
  • Sitemap

Recent posts

  • Price update for Raabkalk from 01.01.2025
  • Article data KW from 1.1.2025
  • Article data Raab from 1.1.2025

Newsletter

Melden Sie sich an, um die neuesten Nachrichten und Produktinformationen zu erhalten.

Returning

You have a technical defect with one of our articles within the warranty period? Then get in touch with us.
Returning

Share this page

  •  
© 2024 Raab-Gruppe. All rights reserved. Terms & Conditions | Privacy policy | Imprint | Webdesign Munich
  • German
EmailLinkedInGoogle Business
Page load link
Change Location
Find awesome listings near you!
Go to Top