Skip to content
+49 (0)2631 913-0|info@raab-gruppe.de
  • Raab-Academy
  • Career
  • Encyclopedia
  • FAQ
  • Sitemap
  • German
Raab-Gruppe Logo Raab-Gruppe Logo Raab-Gruppe Logo
  • Home
  • Brands
    • Raab
      • Raab Academy
      • Raab-Center
      • Planning software
    • Kutzner + Weber
      • Services
        • Sound measurement
        • Funding programms
    • NET
      • Services
      • Industry solutions
        • Bakery industry
        • Commerce and industry
  • Products
    • Raab
      • Alloy surcharge
      • Air-Stream
      • DW
      • DW-Alkon
      • EW
      • EW-Alkon
      • EW-Flex
      • Synthetic gas flue systems
      • LB LAS-FB
      • LB shaft L90
      • LB Universal
      • Super-Flex
      • Accessories for chimney cowl
      • Wall duct
    • Kutzner+Weber
      • Flue gas damper
      • Particle separator
      • Chimney fan
      • Silencer
      • Draught regulator
      • Accessories
    • NET
      • General description heat exchanger
      • Thermojekt® G and GB
      • Thermojekt® R and RB
      • Thermojekt® SK
      • Control engineering
      • Accessories for NET heat exchanger
  • Downloads
    • Raab
      • Approval & Planning
      • Assembly instructions
      • Brochures & Price Lists
      • Datanorm article data
      • Order forms
      • Product brochures
    • Kutzner+Weber
      • Assembly instructions
      • Brochures
      • Certificates
      • Datanorm article data
      • Pricelists
    • NET
  • References
  • News & Events
    • News
    • Events
    • Web-Seminare
  • About us
    • Company
      • History
      • Chronicle
    • Quality management
      • Certification
      • Disposal
    • Career
  • Contact
    • Distribution partners

INJEKT

  1. You are here:
  2. Home
  3. Portfolio
  4. INJEKT
INJEKTHeartbit2023-01-06T16:50:58+01:00
  • Description

  • Application area

  • Benefits

  • Type series

  • Downloads

  • FAQ

  • Description

The problem

Draught problems in the chimney can occur due to unfavorable weather conditions, an unfavorable positioning of the chimney or a faulty design of the flue gas system. In this case, the flue gases are no longer reliably removed and affect the operational safety of the flue gas system of the fireplace.
The solution

When the natural draft is too weak, the INJEKT chimney fan provides reliable and optimal draft in the chimney again.

Flue gas systems and chimneys must be designed in such a way that the negative pressure required for safe flue gas routing is always present. This makes the INJEKT a safety-relevant component that enables safe acceptance by the chimney sweeper in the event of draught problems.

The mode of operation

The INJEKT chimney fan is mounted on the chimney outlet and creates a safe draught in the chimney thanks to its electric fan.

A special feature of INJEKT is the external technology. The INJEKT uses a fluidic law to arrange all mechanical components outside the cross-section of the stack.

The assembly

The compact dimensions as well as the low weight allow easy mounting on the outlet of all conventional and metal flue gas systems. To control the blower, a power supply line must be laid from the chimney to the fireplace.

The control

The fan of the INJEKT chimney fan can be infinitely varied in speed. This allows you to individually create the necessary draught (e.g. high draught during heating, low draught during glowing). The control can be manual or automatic. Manual control is performed by a speed controller (RS controller), which is well placed in the immediate vicinity of the fireplace.

As a component of the K+W stove control system, it is automatically controlled and only runs when it is needed – at the optimum speed for the respective combustion phase. For maintenance work by the chimney sweeper, the INJEKT chimney fan can be taken out of operation via a service switch directly at the cleaning point. Because the INJEKT chimney fan is only switched on when needed, it is economical in terms of energy consumption.

  • Application area

The INJEKT chimney fan is particularly suitable for fireplaces with solid fuels that are sensitive to draught, e.g.: Wood, pellets, wood chips, etc.

In conjunction with the furnace control system, it is an effective component within the control system for reducing emissions and increasing operational safety. For oil and gas fireplaces, the INJEKT chimney fan can provide a remedy in the event of technical or weather-related flue gas problems; please speak to one of our specialist advisors.

  • Benefits

This results in three advantages

  • The chimney cross-section remains open and freely accessible for the chimney sweeper.
  • The technology is located outside the aggressive and hot flue gases and therefore requires little maintenance.
  • The natural draught is maintained. This means that the INJEKT chimney fan does not have to run permanently when there is sufficient draught. The flue gas system remains open even in the case of a power failure and does not obstruct the flow of flue gas.
  • Type series

  • Downloads

Here you have the possibility to download the brochures you are interested in as PDF files.

All brochures

Produktblatt INJEKT– Der Rauchsauger (PDF)

  • FAQ

Frequently asked questions and answers about chimney fans

FAQ

Products

  • Raab
    • Air-Stream
    • DW
    • DW-Alkon
    • EW
    • EW-Alkon
    • EW-Flex
    • Synthetic gas flue systems
    • LB shaft L90
    • LB Universal
    • LB LAS-FB
    • Super-Flex
    • Accessories for chimney cowl
    • Wall duct
  • Kutzner+Weber
    • Flue gas damper
      • IK 250
      • Motor-driven flue gas dampers
      • Thermally controlled flue gas dampers
    • Particle separator
    • Chimney fan
    • Silencer
    • Draught regulator
    • Accessories
  • NET
    • Thermojekt® G and GB
    • Thermojekt® R and RB
    • Thermojekt® SK
    • Accessories for NET heat exchanger

Informations

  • Raab Academy
  • Career
  • Downloads
  • Internal Downloads Login
  • Encyclopedia
  • FAQ
  • Sitemap

Recent posts

  • Price update for Raabkalk from 01.01.2025
  • Article data KW from 1.1.2025
  • Article data Raab from 1.1.2025

Newsletter

Melden Sie sich an, um die neuesten Nachrichten und Produktinformationen zu erhalten.

Returning

You have a technical defect with one of our articles within the warranty period? Then get in touch with us.
Returning

Share this page

  •  
© 2024 Raab-Gruppe. All rights reserved. Terms & Conditions | Privacy policy | Imprint | Webdesign Munich
  • German
EmailLinkedInGoogle Business
Page load link
Change Location
Find awesome listings near you!
Go to Top